  "manufacturer": "TATPROF",
  "system_family": "TPT95",
  "branch": "doors",
  "status": "CATALOG_CLOSED",
  "source": {
    "type": "official_pdf",
    "url": "https://www.tatprof.ru/upload/iblock/b32/%D0%A2%D0%9F%D0%A2-95.pdf",
    "pages": 101,
    "title": "ТПТ-95 — блоки оконные и дверные"
  },
  "current_door_page": "https://www.tatprof.ru/products/arkhitekturnaya-sistema/dveri-tpt-95/",
  "passport_catalog": {
    "depth_mm": 95,
    "thermal_bridge_mm": 50,
    "installation_variants": [
      "opening",
      "facade"
    ],
    "middle_coextruded_seal": true,
    "rebate_insulation_insert": true
  },
  "passport_web_2026": {
    "glazing": "more than 44 mm",
    "Rpr_m2C_W": "from 0.8",
    "max_sash_height_mm": 2500,
    "max_sash_width_mm": 1200,
    "profile_wall_mm": 2,
    "seal_contours": 3,
    "rebate_clearance_mm": 16,
    "opening": "outward swing",
    "leaves": [
      "single",
      "double",
      "unequal double"
    ],
    "fill_types": [
      "glazed",
      "solid",
      "combined"
    ],
    "glazing_principle": "bead",
    "hinges": [
      "surface"
    ],
    "threshold": "rebated"
  },
  "key_profiles": {
    "95.02.01": "door frame, opening, outward",
    "95.02.02": "door frame, facade, outward",
    "95.02.03": "door sash",
    "95.02.04": "door sash impost",
    "95.02.07": "door meeting stile",
    "95.07.02": "seal holder above threshold",
    "95.07.03": "adapter for frame in facade",
    "95.08.01": "door corner connector",
    "95.08.02": "insert for 95.02.01/02",
    "65.08.01": "T-connector"
  },
  "hardware_examples": {
    "hinges": [
      "Fapim Loira 7010V",
      "Fapim Loira 7013V",
      "STN-1420-04 up to 150 kg",
      "STN-1420-14 up to 180 kg"
    ],
    "locks": [
      "KALE 15330",
      "KFV 50 PZ/F24/30"
    ],
    "closer": "DORMA TS92",
    "cylinder": "DOM 6SR 35/85"
  },
  "single_door_example": {
    "profiles": [
      "95.02.01",
      "95.02.03",
      "95.02.04"
    ],
    "fill_cut_formulas": [
      "H-H1-168",
      "H1-127.5",
      "B-270"
    ],
    "other": "95.07.02 = B-156",
    "scope": "only source drawing 06-02/06-03"
  },
  "double_door_example": {
    "profiles": [
      "95.02.01",
      "95.02.03",
      "95.02.07",
      "95.02.04"
    ],
    "scope": "06-06 onward; B/2 deductions require visual verification"
  },
  "warnings": [
    "hinge load is not system max door weight",
    "current separate door PDF needs diff against combined 101p source",
    "static section uses legacy SNiP; recalc to current SP",
    "do not copy machining between hardware models"
  ]
}